Temperature Control System |
Host of a section of the temperature is too high |
1. Cooling system failure (water)
1.1 solenoid valve did not work
1.2 cut-off valve to close the road
1.3 cooling water pipe plug
2. Cooling system failure (air)
2.1 fan did not work
2.2 fans not to switch
2.3 small air movements
3. PLC temperature control or regulation of failure
4. SSR or damage Triac
5. Screw combination of strong cut-off |
1.1 solenoid valve wiring inspections, inspection or replacement of the solenoid valve.
1.2 open valve to regulate the flow to the right location.
1.3 cooling water pipes to clear the way
2.1 fan wiring inspections, inspection or replacement of the fan
2.2 connection to adjust fan
2.3 small reset switch air temperature
3.1 to amend or adjust PLC parameters, and then Observation
3.2 temperature checks or PLC, the replacement of temperature control or PLC module
4. Replacement of solid-state relay or two-way thyristor
5. Portfolio adjustment screw |
Host of a section of the low temperature |
1. PLC temperature control or regulation of failure
2. Small heater power
3. Cooling system failure (water)
3.1 cooling water temperature on the low side
3.2 solenoid valve spool stuck
3.3 cut-off valve open through the big
4. Portfolio not screw shear
5. Host screw speed on the low side
|
1.1 to amend or PLC-conditioning temperature control parameters, and then observed
2. Replacement of large power
3.1 heater cooling water temperature increased, and then observed
3.2 cooling water temperature increased, and then observed
3.3 check valve, regulator and opening
4. Adjustment screw combination
5. Screw speed will be increased appropriately, and then observed |
Host system |
Automatic parking |
1. Cooling fan stopped
2. Lubricating oil pump stopped
3. Lubricating oil pressure is too high or too low
4. Melt pressure gauge
5. Governor faults (lack of phase, under-voltage, over-current, overload, overheating, and so on)
6. Host system and other accessory equipment failure of the chain |
1. To stop identifying the causes, management resolved to restart
2. To stop identifying the causes, management resolved to restart
3. Clean or replace the oil filter
4.1 check melt pressure alarm settings is appropriate
4.2 head replacement filters
4.3 nose temperature is too low
4.4 nose module to plug holes if
5. Manual control governor resolve to deal with, overload, over-current phenomenon should check:
5.1 Host screw it hard to enter foreign body
5.2 host the temperature is set too low
5.3 feed volume is too large, granular feed is too large
5.4 screw components, transmission gear box bearing damage is
6. To identify the reasons for failure, dealing with the re-start |
Feeding System |
Automatic parking |
1. Main Motor stop
2. Failure governor
3. Mechanical failure |
1. Check the host system to deal with some of the
2. Manual control governor dealing with the
3. Please machinery, electrical inspection staff to deal with (Feeder whether foreign body, feed particles is too large, whether in the form of Feeder and materials do not match) |
Lubrication system |
Pump not working |
1. Did not start
2. Overload
3. Mechanical failure |
1. To identify the reasons for stopping pumps to deal with after the restart to solve
2. Please machinery, electrical inspection staff to deal with |
Oil pressure warning |
1. Oil off oil
2. Dirty oil filter blocking
3. Set too low oil pressure
4. Lubricating oil viscosity is too high |
1. Please mechanical inspection staff to deal with
2. Clean or replace the oil filter
3. Reset oil
4. Replacement of low-viscosity grade lubricants |
Cooling water system |
Pump not working |
1. Did not start
2. Overload
3. Mechanical failure |
1. To identify the reasons for stopping pumps, dealing with the re-start |
Cooling water does not pass |
1. Pump did not work
2. Solenoid valve is not open
3. Cut-off valve is not open
4. Lack of water tanks
5. Pump intake plug
6. Abnormal pump |
1. Reference to the section on
2.1 Check electrical lines
2.2 check electromagnetic valve replacement or
3. Check valve replacement or
4. Provides water to the water level
5. Clean-up outlet
6. Please machinery, electrical inspection staff |
Vacuum system |
Vacuum pump is not working |
1. Did not start
2. Overload
3. Mechanical failure |
1. To identify the reasons for stopping pumps to deal with after the restart to solve
2. Please machinery, electrical inspection staff |
Vacuum table without instructions |
1. Vacuum pumps did not work
2. Road tube condensation can not open the valve
3. Vacuum system leakage
4. Vacuum pump inlet valve is not open or opened too small to spend large
5. I plug the vacuum pump emissions |
1. Reference to the section on
2. Open the valve
3. Please mechanical inspection staff to deal with
4. Water conditioning vacuum pump and open the valve
5. I clean up emissions so smooth |